Bathroom Exhaust Fan Size Calculator (CFM)
What CFM bathroom fan to buy: the ASHRAE 62.2 / IRC minimum and the ENERGY STAR pick for intermittent or continuous operation, from PNNL's Building America guide.
Formula
Code minimum: ≥50 cfm intermittent or ≥20 cfm continuous (ASHRAE 62.2 / IRC M1507). ENERGY STAR pick on the PNNL guide: ≥70 intermittent; >50 when targeting continuous ≥20.
Worked example
Inputs: How the fan will run = Intermittent (switch / humidity); Desired CFM (0 = use ENERGY STAR pick) = 0 cfm.
| Ashrae irc minimum cfm | 50 |
|---|---|
| Energy star recommended cfm | 70 |
| Selected cfm | 70 |
| Operation | intermittent |
PNNL Building America Solution Center, Bathroom Exhaust Fans: ASHRAE 62.2 (2010) and IRC 2021 Section M1507 require ≥50 cfm intermittent or ≥20 cfm continuous local exhaust, ducted outdoors. ENERGY STAR guidance on that page: pick at least 70 cfm for intermittent (≥50 code) and a fan rated over 50 cfm when targeting continuous ≥20 cfm. Prefer ≤3 sones intermittent or ≤1 sone continuous.
FAQ
What size bathroom fan do I need?
For a typical switch-operated fan: at least 50 cfm by code, and ENERGY STAR recommends buying 70 cfm or more so installed airflow still meets 50.
Continuous vs intermittent?
Continuous needs ≥20 cfm; intermittent needs ≥50 cfm when it runs (ASHRAE 62.2 / IRC).
Why buy a larger fan than the minimum?
Duct length and elbows cut real airflow. PNNL/ENERGY STAR: pick ~70 cfm intermittent so you still deliver 50 at the grille.
Where should it exhaust?
Directly outdoors — not into an attic, crawlspace or soffit cavity (PNNL).
How quiet should it be?
ENERGY STAR: ≤3 sones intermittent or ≤1 sone continuous.
Sources
Related
- Dehumidifier Size Calculator (Pints per Day by Room Size)
- Attic Ventilation Calculator (Net Free Area, Ridge & Soffit Vents)
- Ceiling Fan Size Calculator (Blade Span by Room Size)
More HVAC calculators
Embed this calculator
Free to embed on your site; please keep the credit link.
Last reviewed 2026-11-20.