Manning's Equation Pipe Flow Calculator (Full & Partial Flow, Pipe Size)
Gravity flow and velocity in a circular pipe at any depth from Manning's equation, plus the smallest full-flow diameter for a design flow, with FHWA roughness values.
Formula
V = (1.49 ÷ n) × R^(2/3) × S^(1/2); Q = V × A. Partial depth: θ = 2·acos(1 − 2y/D), A = D²(θ − sin θ)/8, P = Dθ/2, R = A/P. Full: R = D/4, Q = (0.464/n)·D^(8/3)·S^(1/2), so D = (Q·n ÷ 0.464√S)^(3/8).
Worked example
Inputs: Pipe inside diameter = 15 in; Pipe slope = 0.8 %; Manning's n = 0.011; Flow depth (100 = full) = 100 % of diameter; Design flow to size a pipe (optional) = 0 cfs.
| Flow cfs | 6.847 |
|---|---|
| Flow gpm | 3,073 |
| Velocity fps | 5.58 |
| Full flow cfs | 6.847 |
| Flow area sq ft | 1.227 |
| Hydraulic radius ft | 0.313 |
| Required diameter in | — |
| Next 3in pipe size in | — |
Manning's equation (FHWA HEC-22, 4th ed., Eq. 4.5 / 9.1–9.2): V = (1.49/n)·R^(2/3)·S^(1/2), Q = V·A; circular segment: θ = 2·acos(1 − 2y/D), A = D²(θ − sin θ)/8, wetted perimeter = Dθ/2. Full pipe: R = D/4. Required full-flow diameter D = [Q·n ÷ (0.464·S^0.5)]^(3/8). n from HEC-22 Table 9.1: concrete pipe 0.010–0.011 (HEC-22 Example 9.1 uses 0.013), PVC 0.009–0.011, smooth corrugated PE 0.009–0.015, corrugated PE 0.018–0.025, corrugated metal 0.022–0.037. Peak capacity occurs near 93% depth; half-full velocity equals full velocity.
FAQ
What is Manning's equation for pipe flow?
V = (1.49/n) R^(2/3) S^(1/2) in US units, with R the hydraulic radius (D/4 for a full pipe) and S the slope in ft/ft. Flow Q = V × area.
FHWA worked example?
HEC-22: a 15 in pipe at 0.8% with n = 0.011 flowing full runs 5.58 ft/s (about 6.8 cfs). Example 9.1 sizes 17.6 cfs at 1.5% with n = 0.013 to 1.69 ft (20.3 in) and picks a 21 in pipe; this page gives 20.2 in because it uses 0.464 instead of the rounded 0.46.
What Manning's n should I use?
HEC-22 Table 9.1: concrete pipe 0.010–0.011, PVC 0.009–0.011, smooth-interior corrugated polyethylene 0.009–0.015, corrugated polyethylene 0.018–0.025, corrugated metal 0.022–0.037. Higher n is more conservative.
Is a half-full pipe half the flow?
Flow is half of full, but velocity is the same as full. Peak capacity occurs at about 93% depth, so designing for full flow is slightly conservative.
Can I use it for a French drain?
For the solid outlet pipe, yes. Perforated pipe in gravel is limited by how fast water reaches it; see the French drain calculator.
Sources
Related
- Rational Method Calculator (Stormwater Runoff Q = CiA, Weighted C)
- French Drain Calculator (Gravel, Pipe, Slope & Fabric)
- Gutter & Downspout Size Calculator (Roof Runoff, Gutter Capacity, Number of Downspouts)
More Plumbing calculators
- Tankless Water Heater Size Calculator (GPM, Temperature Rise, BTU & kW)
- Water Softener Size Calculator (Grains per Day and Capacity)
- Well Pressure Tank Size Calculator (Drawdown and Pump Run Time)
- Rainwater Harvesting Calculator (Gallons from Your Roof)
Embed this calculator
Free to embed on your site; please keep the credit link.
Last reviewed 2026-11-20.