French Drain Calculator (Gravel, Pipe, Slope & Fabric)
How much gravel, perforated pipe and filter fabric a French drain needs: trench volume minus the pipe, tons of stone, the drop for a 1-in-per-8-ft slope, and wrap area — using LSU AgCenter and Norfolk VA trench sizes.
Formula
Gravel cu ft = length × width × gravel depth − π × (OD ÷ 24)² × length, then × (1 + waste). Tons = cu ft × density ÷ 2,000. Slope drop = length ÷ 8 (1 in per 8 ft). Fabric ≈ (width + 2 × depth + 1 ft) × length.
Worked example
Inputs: Trench length = 50 ft; Trench width = 12 in; Trench depth = 18 in; Pipe outside diameter (0 = no pipe) = 4.215 in; Gravel fill depth (0 = fill the trench) = 0 in; Waste allowance = 10 %; Gravel density = 105 lb/cu ft; Filter fabric wrap = Yes — wrap trench.
| Trench cu ft | 75 |
|---|---|
| Gravel cu ft | 77.17 |
| Gravel cu yd | 2.86 |
| Gravel tons | 4.05 |
| Pipe ft | 50 |
| Slope drop in at 1 in per 8 ft | 6.25 |
| Fabric sq ft | 250 |
| Bags 0 5 cf | 155 |
Trench volume minus the pipe cylinder (outside diameter). LSU AgCenter P3879: typical French drain trench 12–18 in wide and 18–24 in deep with a 4 in perforated pipe in washed gravel. City of Norfolk VA Infiltration guide: trench at least 12 in × 18 in, slope 1 in per 8 ft. Fabric wrap ≈ (width + 2 × depth + 1 ft overlap) × length. Density default ~105 lb/cu ft (~1.4 t/yd³); use your supplier figure. Not a hydraulic design.
FAQ
How wide and deep should a French drain be?
LSU AgCenter: typically 12–18 in wide and 18–24 in deep with a 4 in perforated pipe. Norfolk: at least 12 in wide by 18 in deep.
What slope does a French drain need?
Norfolk: slope the trench and pipe 1 in for every 8 ft toward the outlet (about 1%).
How much gravel for a 50 ft French drain?
A 50 ft × 12 in × 24 in trench around a 4 in pipe needs about 4.0 cu yd (≈5.7 tons at 105 lb/cu ft) with 10% waste.
Do I need fabric?
A geotextile wrap keeps soil out of the gravel (LSU). Sock-wrapped pipe still benefits from a trench liner in silty soil.
What pipe size?
Residential French drains commonly use 4 in perforated pipe (LSU). Enter the outside diameter so the calculator can subtract the pipe volume.
Sources
- LSU AgCenter Publication 3879, Landscape Ornamental Series: Installing and Maintaining a French Drain: trench typically 12–18 in wide and 18–24 in deep with a 4 in perforated pipe in washed gravel (about 1 in), often lined with geotextile
- City of Norfolk, Virginia, Infiltration (French drain / infiltration trench) guide: trench no less than 12 in wide by 18–24 in deep; pipe and trench slope 1 in for every 8 ft
Related
- Mulch, Gravel & Topsoil Calculator (Cubic Yards)
- Gutter & Downspout Size Calculator (Roof Runoff, Gutter Capacity, Number of Downspouts)
- Retaining Wall Block Calculator (Blocks, Caps, Base Gravel & Drainage Rock)
More Landscape calculators
- Paver Calculator (Pavers, Base Gravel & Sand)
- Sod Calculator (Square Feet, Pieces & Pallets)
- Lawn Fertilizer Calculator (Pounds per 1,000 Sq Ft from N-P-K)
- Grass Seed Calculator (Pounds of Seed for a New Lawn)
- Trench Sloping Calculator (OSHA Soil Type A, B, C Slopes & Volume)
- Rational Method Calculator (Stormwater Runoff Q = CiA, Weighted C)
Embed this calculator
Free to embed on your site; please keep the credit link.
Last reviewed 2026-11-20.