Rational Method Calculator (Stormwater Runoff Q = CiA, Weighted C)
Peak stormwater runoff in cfs and gpm from rainfall intensity and up to three land-cover areas, with the area-weighted runoff coefficient, using the FHWA HEC-22 Rational Method.
Formula
Q (ft³/s) = C × I (in/h) × A (acres), Ku = 1.0 (HEC-22 Eq. 4.1). Weighted C = Σ(C·A) ÷ ΣA (Eq. 4.2). gpm = cfs × 448.83. 1 acre = 43,560 sq ft.
Worked example
Inputs: Rainfall intensity (design storm, duration = tc) = 2.3 in/h; Area 1 = 5.4 acres; Runoff coefficient C, area 1 = 0.9; Area 2 (0 = none) = 1.6 acres; C, area 2 = 0.15; Area 3 (0 = none) = 36.3 acres; C, area 3 = 0.236.
| Peak flow cfs | 31.43 |
|---|---|
| Peak flow gpm | 14,108 |
| Weighted c | 0.316 |
| Total area ac | 43.3 |
| Total area sq ft | 1,886,148 |
| Area check | Under 200 ac: within the Rational Method range |
FHWA HEC-22 (4th ed., 2024) Eq. 4.1: Q = C·I·A ÷ Ku, Ku = 1.0 in US units (Q in ft³/s, I in in/h, A in acres); weighted C = Σ(Cx·Ax) ÷ A (Eq. 4.2); typical C from Table 4.1 (ASCE). I is the design-storm intensity for a duration equal to the time of concentration, read from your local IDF curve (e.g. NOAA Atlas 14). 1 ft³/s = 448.83 gal/min. Use under 200 acres.
FAQ
What is the rational method formula?
Q = CiA: peak flow in cfs equals the runoff coefficient times rainfall intensity in inches per hour times drainage area in acres (the unit factor is 1.008, taken as 1.0).
What runoff coefficient should I use?
HEC-22 Table 4.1 (ASCE): roofs 0.75–0.95, asphalt 0.70–0.95, concrete 0.80–0.95, drives and walks 0.75–0.85, lawns on sandy soil 0.05–0.20, lawns on heavy soil 0.13–0.35, single-family residential 0.30–0.50. Use the high end for steep sites and rarer storms.
FHWA worked example?
HEC-22 Example 4.3: proposed C = 0.315 on 43.3 ac with I = 2.3 in/h gives Q = 31.4 cfs (the defaults on this page reproduce it).
Where do I get rainfall intensity?
From your local IDF curve or NOAA Atlas 14, for a storm duration equal to the time of concentration and your design return period (e.g. 10-year).
How big an area can I use it for?
FHWA (HDS-2) recommends it for drainage areas under 200 acres; above that, use a hydrograph method such as NRCS.
Sources
- FHWA, HEC-22 Urban Drainage Design, 4th edition (FHWA-HIF-24-006, Feb 2024), 4.2.2 Rational Method: Eq. 4.1 Q = CIA/Ku (Ku = 1.0 US), Eq. 4.2 weighted C, Table 4.1 runoff coefficients, Example 4.3; use under 200 ac
- NOAA National Weather Service, Precipitation Frequency Data Server (Atlas 14): rainfall intensity by duration and return period for your location
Related
- French Drain Calculator (Gravel, Pipe, Slope & Fabric)
- Retaining Wall Block Calculator (Blocks, Caps, Base Gravel & Drainage Rock)
- Gutter & Downspout Size Calculator (Roof Runoff, Gutter Capacity, Number of Downspouts)
More Landscape calculators
- Mulch, Gravel & Topsoil Calculator (Cubic Yards)
- Paver Calculator (Pavers, Base Gravel & Sand)
- Sod Calculator (Square Feet, Pieces & Pallets)
- Lawn Fertilizer Calculator (Pounds per 1,000 Sq Ft from N-P-K)
- Grass Seed Calculator (Pounds of Seed for a New Lawn)
- Trench Sloping Calculator (OSHA Soil Type A, B, C Slopes & Volume)
Embed this calculator
Free to embed on your site; please keep the credit link.
Last reviewed 2026-11-20.