Heat Index Calculator (NWS Formula, Danger Levels & OSHA Heat Notes)
Heat index from air temperature and relative humidity using the National Weather Service equation, with the NWS risk category and what it means for outdoor work.
Formula
Simple: HI = 0.5 × (T + 61 + (T − 68) × 1.2 + 0.094 × RH), averaged with T. If ≥ 80 °F: HI = −42.379 + 2.04901523T + 10.14333127RH − 0.22475541T·RH − 0.00683783T² − 0.05481717RH² + 0.00122874T²RH + 0.00085282T·RH² − 0.00000199T²RH², with NWS low/high humidity adjustments.
Worked example
Inputs: Air temperature (shade) = 96 °F; Relative humidity = 65 %.
| Heat index °F | 121 |
|---|---|
| Heat index c | 49.5 |
| Nws category | Danger |
| Method | Rothfusz regression |
| In direct sun up to °F | 136 |
NWS/WPC heat index equation (Rothfusz 1990, SR 90-23; simple Steadman form averaged with T first, full regression if that is 80 °F or more; regression error ±1.3 °F). Categories from NWS: Caution 80–90, Extreme Caution 90–103, Danger 103–124, Extreme Danger 125+ °F. Heat index is for shade; NWS says direct sun can add up to 15 °F. OSHA: heat index is a screening tool only, workers have died at a daily max heat index of 86 °F, and WBGT measured on site is preferred.
FAQ
What is the heat index at 96 °F and 65% humidity?
About 121 °F, in the NWS Danger range (103–124 °F).
What heat index is dangerous?
NWS: 103–124 °F is Danger and 125 °F or more is Extreme Danger. Heat illness is possible from 80 °F with prolonged exposure or activity.
Does the heat index include sun?
No. It is a shade value; NWS says full sunshine can raise it by up to 15 °F (OSHA cites up to 13.5 °F).
Is heat index enough for job sites?
OSHA calls it a screening tool. Workers have died at a daily maximum heat index of 86 °F; on-site WBGT plus workload is the better assessment.
How accurate is the heat index formula?
The Rothfusz regression has an error of about ±1.3 °F against the original tables.
Sources
- NOAA NWS Weather Prediction Center, The Heat Index Equation (Rothfusz regression, SR 90-23; low- and high-humidity adjustments; simple Steadman formula below about 80 °F)
- NOAA NWS Amarillo, Heat Index: Caution 80–90 °F, Extreme Caution 90–103 °F, Danger 103–124 °F, Extreme Danger 125 °F or higher; full sun can add up to 15 °F
- OSHA, Heat Hazard Recognition: heat index is a screening tool; outdoor workers have died at a daily maximum heat index of 86 °F; on-site WBGT preferred
Related
- Wind Chill Calculator (NWS Formula, °F and °C)
- Dew Point Calculator (Painting, Coating & Condensation Check)
- Dehumidifier Size Calculator (Pints per Day by Room Size)
More Safety calculators
- Noise Exposure Calculator (OSHA Noise Dose % & 8-Hour TWA)
- Sling Angle Calculator (Rigging Load Angle Factor & Tension per Leg)
- NIOSH Lifting Equation Calculator (RWL & Lifting Index)
- 8-Hour TWA Calculator (OSHA Time-Weighted Average & Mixture Formula)
- Porta Potty Calculator for Job Sites (OSHA Toilet Requirements per Worker)
Embed this calculator
Free to embed on your site; please keep the credit link.
Last reviewed 2026-11-20.